Acta Crystallographica · 1959 · 63 citations · 0 references
Natural SciencesChemistryAnalytical ChemistryRadiation MeasurementSpectroscopyCrystal ChemistryCrystallographyCounting Error AnalysisDiffraction Data CollectionStatistical ErrorSystematic Errors
Two independent, three-dimensional sets of intensity data have been collected from two different crystals of basic beryllium acetate (Be40(CH3COg)8 , cubic, /~d3, a 0 = 15.74 A, Z = 8). An Eulerian cradle Geiger counter spectrometer was employed for the measurements. Two crystals were surveyed so as to insure against systematic errors in the data. The integrated intensities of the two sets of data were obtained in different ways, one by stationary crystal-stationary counter and the other by moving crystal-moving counter. Each set of data is affected by a different kind of statistical counting error (constant count, fixed time count). The intensities of seven strong low order reflections that are affected by extinction ha the data crystals have been detelznlued from the consideration of two additional smaller crystals and a powder. The reproducibility of equivalent reflections has been tested in two different ways and has been found to be about 4 % in intensity. A detailed comparison of the two sets of data has been carried out. The overall agreement, all reflections included, is of the order of 8 % in intensity.