Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2011 · 45 citations · 0 references
EngineeringNuclear EngineeringNuclear InstrumentationRadiation DetectionRadiation MeasurementX-ray DetectionX-ray DetectorsX-ray OpticsDevice DiagnosticsPoisson Counting StatisticsPosition SensitivityPosition-sensitive DetectorsPrecisionRelative PrecisionSensitivityX-ray Source Characterization
An inline diagnostics device was developed to measure the intrinsic shot-to-shot intensity and position fluctuations of the SASE-based LCLS hard X-ray FEL source. The device is based on the detection of back-scattered X-rays from a partially-transmissive thin target using a quadrant X-ray diode array. This intensity and position monitor was tested for the first time with FEL X-rays on the XPP instrument of the LCLS. Performance analyses showed that the relative precision for intensity measurements approached 0.1% and the position sensitivity was better than 5 μm, limited only by the Poisson statistics of the X-rays collected in a single shot.