Medical Physics · 2001 · 250 citations · 31 references
MedicineBiomedical EngineeringRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingChest RadiologyComputed TomographyComputer-aided DiagnosisMedical Image AnalysisPulmonary ImagingVolume SegmentationComputer-aided Nodule AnalysisLinear Discriminant AnalysisLung Volume QuantificationNodule Morphology AssessmentPulmonary Nodule DiagnosisThoracic Malignancy DetectionThoracic SegmentationThresholds
We have developed a fully automated computerized method for the detection of lung nodules in helical computed tomography (CT) scans of the thorax. This method is based on two-dimensional and three-dimensional analyses of the image data acquired during diagnostic CT scans. Lung segmentation proceeds on a section-by-section basis to construct a segmented lung volume within which further analysis is performed. Multiple gray-level thresholds are applied to the segmented lung volume to create a series of thresholded lung volumes. An 18-point connectivity scheme is used to identify contiguous three-dimensional structures within each thresholded lung volume, and those structures that satisfy a volume criterion are selected as initial lung nodule candidates. Morphological and gray-level features are computed for each nodule candidate. After a rule-based approach is applied to greatly reduce the number of nodule candidates that corresponds to nonnodules, the features of remaining candidates are merged through linear discriminant analysis. The automated method was applied to a database of 43 diagnostic thoracic CT scans. Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate nodule candidates that correspond to actual nodules from false-positive candidates. The area under the ROC curve for this categorization task attained a value of 0.90 during leave-one-out-by-case evaluation. The automated method yielded an overall nodule detection sensitivity of 70% with an average of 1.5 false-positive detections per section when applied to the complete 43-case database. A corresponding nodule detection sensitivity of 89% with an average of 1.3 false-positive detections per section was achieved with a subset of 20 cases that contained only one or two nodules per case.
31
Robert T. Greenlee, M. B. Hill-Harmon, Thomas S. Murray et al. · CA A Cancer Journal for Clinicians · 2001 · 3.3K citations · Full text
Early Lung Cancer Action Project: overall design and findings from baseline screening
Claudia I. Henschke, Dorothy I. McCauley, David F. Yankelevitz et al. · The Lancet · 1999 · 2.5K citations · Full text
Mass screening for lung cancer with mobile spiral computed tomography scanner
Shusuke Sone, Shodayu Takashima, Feng Li et al. · The Lancet · 1998 · 942 citations
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Masahiro Kaneko, K. Eguchi, Hironobu Ohmatsu et al. · Radiology · 1996 · 841 citations