IR-Thermographic Screening of Thermoneutral or Endothermic Transformations: The Ring-Closing Olefin Metathesis Reaction

Manfred T. Reetz, Michael Becker, Monika Liebl, Alois Fürstner

Angewandte Chemie International Edition · 2000 · 77 citations · 0 references

Concepts

Abstract

Provided that the heat of vaporization of a volatile product leads to a change in temperature, as, for example, in ring-closing olefin metathesis (RCM) reactions [Eq. (1)], endothermic or even thermoneutral processes can be subjected to high-throughput screening by an IR-thermographic detection system, a method which was originally designed to screen exothermic reactions.