Publication | Closed Access
The optimal stack spacing for thermoacoustic refrigeration
116
Citations
8
References
2002
Year
Characteristic Pore DimensionPlate SpacingEngineeringHeat ExchangerMechanical EngineeringPenetration DepthThermodynamicsHeat TransferThermoacoustic Heat EngineThermal EngineeringAlternative RefrigerantOptimal StackRefrigeration
The characteristic pore dimension in the stack is an important parameter in the design of thermoacoustic refrigerators. A quantitative experimental investigation into the effect of the pore dimensions on the performance of thermoacoustic devices is reported. Parallel-plate stacks with a plate spacing varying between 0.15 and 0.7 mm are manufactured and measured. The performance measurements show that a plate spacing in the stack of 0.25 mm (2.5 deltak) is optimum for the cooling power. A spacing of 0.4 mm (4 deltak) leads to the lowest temperature. The optimum spacing for the performance is about 0.3 mm (3 deltak). It is concluded that a plate spacing in the stack of about three times the penetration depth should be optimal (3 deltak) for thermoacoustic refrigeration.
| Year | Citations | |
|---|---|---|
Page 1