Gait AnalysisEngineeringWrist StrapWearable TechnologySafety ScienceNew International StandardFloor/footwear SystemMovement AnalysisKinesiologyUnmanned Ground VehicleSystems EngineeringApplied PhysiologyKinematicsGround ControlHealth SciencesPhysical MedicineEsd Sensitive DevicesRehabilitationAutomationPodiatryHuman Movement
The new international standard dealing with the protection of ESD sensitive devices (IEC 1340-5-1) allows that people working in a standing position are grounded via the system floor/footwear (without using a wrist strap). In this case the resistance to ground R <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">TG</sub> should be the same as for wrist straps (< 35 MΩ). This paper shows that normally for walkmg or working in a standing position a value of 109L2 for the resistance to ground of the system floor/footwear is sufficient.