International Current Pharmaceutical Journal · 2012 · 12 citations · 9 references
PharmacyPharmaceutical AnalysisPharmacologyAnalytical ToxicologyChromatographic AnalysisForensic Pharmaceutical AnalysisAnalytical ChromatographyChromatographic Analysis Of PharmaceuticalsChromatographyLiquid ChromatographyAnalytical Liquid ChromatographyCalibration Curve AnalysisChromatographic Drug AnalysisChromatographic ValidationConcentrationDrug Retention TimeHigh-performance Liquid ChromatographyHigh-performance Liquid Chromatography Method Development
A reverse phase high performance liquid chromatographic method was developed for the determination of duloxetine hydrochloride in bulk and dosage form. The separation was effected on a kromasil ODS C18 column (250mmX4.6mm, 5?) using a mobile phase mixture of buffer and methanol in a ratio of 85:15 v/v at a flow rate of 1.0ml/min. The detection was made at 230nm. The retention time of duloxetine hydrochloride was found to be 3.443±0.06 min. Calibration curve was linear over the concentration range of 20-120?g/ml of duloxetine hydrochloride. The propose method was validated as per the ICH guidelines. The method was accurate, precise, specific and rapid found to be suitable for the quantitative analysis of the drug and dosage form.DOI: http://dx.doi.org/10.3329/icpj.v1i5.10281International Current Pharmaceutical Journal 2012, 1(5): 98-102
9
P. Senthamil Selvan, K. Veeran Gowda, Uttam Kumar Mandal et al. · Journal of Chromatography B · 2007 · 33 citations
Suneela Dhaneshwar, Padmanabh B. Deshpande, Ms. Ashwini Dilip Patil et al. · Indian Journal of Pharmaceutical Sciences · 2008 · 33 citations · Full text