Journal of Applied Bacteriology · 1981 · 12 citations · 3 references
AgricultureDairy ScienceMicrobiologyBacteriologyDairy MicrobiologyMilk QualityMilk MicrobiologyMilk MicrofloraMilking EquipmentAcridine Orange TestBacteriological Quality Of MilkClump FormationMicroscopyRapid Detection AssaysRinse Sampling
Membrane filtration and epifluorescent microscopy were used for the rapid enumeration of bacteria in rinses of milking equipment. Rinse solution (10 ml) was filtered through a 0.6 µm pore size Nuclepore membrane filter and the bacteria retained stained with acridine orange. The clump count of orange fluorescing bacteria on the membrane correlated well with the corresponding plate count ( r =0.83). The technique is rapid, taking approximately 10 min, and is sufficiently sensitive to detect 1000 bacteria ml rinse (equivalent to 5 × 10 3 bacteria/m 2 of milking equipment surfaces by the method currently in use).
3