Concepedia

Publication | Closed Access

Evaluation of platelet transfusion triggers in a tertiary‐care hospital

75

Citations

24

References

2006

Year

Abstract

The data show that most patients who receive PLTs have pretransfusion counts of more than 10 x 10(9) per L and more than one-third have pretransfusion counts of greater than 20 x 10(9) per L. The medical literature supports prophylactic PLT transfusion based solely on the count when the PLT number is 10 x 10(9) per L or less. Above this level additional justification is needed although there are different points of view concerning the appropriate triggers. Our data suggest that there is a need for clear hospital transfusion guidelines and ongoing monitoring of PLT use.

References

YearCitations