Operational experience with zirconiated T–F emitters

Julia Wolfe

Journal of Vacuum Science and Technology · 1979 · 18 citations · 0 references

Concepts

Abstract

Additional experience with this type of cathode has added considerable knowledge relative to its characteristics since a report was given by Swanson in 1975 at this conference. The beam current stability is better than ±0.5% at pressures in the region of 10−8 Torr. The source brightness is 109 A/cm2/sr. The operating point is typically 107 V/cm electric field, 1800 K and 105A/cm2. Life tests have indicated life times of 5000 h or greater may be expected at the above operating point and 10−8 Torr vacuum. The virtual source size for our geometry and operating point has been calculated and measured at about 100 Å for an acceptance half angle of 0.015 rad. The zirconiated cathode is also highly recommended for thermionic and Schottky aided thermionic applications. It is more stable and longer lived than LaB6.