Chinese Journal of Chromatography · 2006 · 10 citations · 8 references
Natural SciencesChemistryFood ScienceAnalytical ChemistryFood AnalysisMass Spectrometric AnalysisAnalytical ChromatographyChromatographyExtraction TechniquesInstrumental AnalysisLiquid ChromatographyMetabolite ExtractionAnalytical Method DevelopmentLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisLiquid Chromatography-mass Spectrometry Method DevelopmentSample ConcentrationTandem Mass SpectrometryUltra-performance Liquid Chromatography Method DevelopmentUltra-performance Liquid Chromatography-mass Spectrometry
A comprehensive analytical method based on ultra performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-MS/MS) with negative mode has been developed for the simultaneous determination of twelve glucocorticoids residues in milk. The multi-reaction monitoring mode was employed for the determination. Milk samples were extracted by sonication in a methanol/acetate buffer (pH 5.20) solution, and then defatted with n-hexane. Sample concentration and purification were performed using Oasis HLB, Sep-pak silica and Sep-pak amino-propyl solid phase extraction cartridges. The separation was performed on a Waters ACQUITY UPLC BEH C18 column (100 mm x 1.0 mm i. d., 1.7 microm) with gradient elution using methanol and water (containing 0.1% formic acid) at a flow rate of 0.1 mL/min. Identification of the glucocorticoids was done using retention times and the distribution of diagnostic ion pairs. Quantification of the glucocorticoids was based on the peak areas of the parent ion and a fragment ion with a higher signal. The limits of detection (LOD) of the method were from 0.02 to 0.38 microg/kg and the limits of quantification (LOQ) ranged from 0.07 to 1.27 microg/kg. Average recoveries for the twelve glucocorticoids (spiked at the levels of 2 and 0.4 microg/kg) ranged from 69.3% to 94.3%, with relative standard deviations between 3.5% and 16.7%. Routine tests showed that the method is fast, sensitive and specific for the determination of glucocorticoids residues in milk.
8
Olivia Van den hauwe, Fréderic Dumoulin, Jean‐Philippe Antignac et al. · Analytica Chimica Acta · 2002 · 66 citations
Maurizio Fiori, E. Pierdominici, Francesca Longo et al. · Journal of Chromatography A · 1998 · 61 citations
Olivia Van den hauwe, Fréderic Dumoulin, Christopher T. Elliott et al. · Journal of Chromatography B · 2004 · 51 citations
Nobuhito Shibata, Tara Hayakawa, Kanji Takada et al. · Journal of Chromatography B · 1998 · 49 citations