International Journal of Photoenergy · 2013 · 87 citations · 33 references
EngineeringElectrical EngineeringEnergy SystemsPower ElectronicsRenewable Energy SystemsEnergy System ModelingRenewable EnergyRenewable Energy TechnologySolar CellsSolar Energy SystemsSolar Photovoltaic SystemsHybrid Energy SystemsHybrid Power SystemsHybrid System SizingPhotovoltaic Energy SystemsPhotovoltaic SystemsSolar Hybrid SystemsSolar-wind Hybrid SystemsWind Power Systems
The study develops a sizing procedure for photovoltaic–wind hybrid power systems using existing mathematical models for PV cells, wind turbines, and batteries. The procedure simulates annual performance, total cost, and optimal sizing of PV, wind, and battery components for various hybrid configurations, using measured system performance data and environmental conditions (solar radiation 1700 Wh/m²/day and wind speed 3.43 m/s) to identify the lowest energy cost design. The optimized system achieved an overall electrical efficiency of 72 % with inverter and charge regulator efficiencies of 90 % and 98 %, respectively, and a life‑cycle cost of $0.89 /kWh (LLP = 0.0428).
A sizing procedure is developed for hybrid system with the aid of mathematical models for photovoltaic cell, wind turbine, and battery that are readily present in the literature. This sizing procedure can simulate the annual performance of different kinds of photovoltaic-wind hybrid power system structures for an identified set of renewable resources, which fulfills technical limitations with the lowest energy cost. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Security lightning application is selected, whereas system performance data and environmental operating conditions are measured and stored. This hybrid system, which includes a PV, wind turbine, inverter, and a battery, was installed to supply energy to 24 W lamps, considering that the renewable energy resources of this site where the system was installed were 1700 Wh/m 2 /day solar radiation and 3.43 m/s yearly average wind speed. Using the measured variables, the inverter and charge regulator efficiencies were calculated as 90% and 98%, respectively, and the overall system’s electrical efficiency is calculated as 72%. Life cycle costs per kWh are found to be $0.89 and LLP = 0.0428.
33