Outgassing rate of multilayer insulation materials at ambient temperature

A. P. M. Glassford, C. K. Liu

Journal of Vacuum Science and Technology · 1980 · 25 citations · 0 references

Concepts

Abstract

The ambient temperature outgassing rate of several multilayer insulation materials has been measured for evacuation times of about six days. The material tested included Mylar radiation shields, double and single metallized with aluminum and gold; double and single aluminized Kapton radiation shields of different thicknesses; and three net and two glass fiber-cloth spacer materials. Experimental measurements were made by collecting outgassing flux from an effusion cell-type sample holder on a liquid-nitrogen-cooled quartz crystal microbalance. The absolute accuracy, measurement range, degree of resolution, and other features of this technique are discussed in detail. The physical phenomena controlling outgassing rate are discussed. It is concluded that long-term outgassing of the metallized shields is probably controlled by degassing of the metallized surfaces. On this assumption empirical equations are proposed for estimating long-term outgassing rates. Data from previous measurement programs are evaluated and compared with the new data as a standard.