Biotechnology and Bioengineering · 2006 · 151 citations · 37 references
Life SciencesBiochemistryAnalytical ChemistryElectroanalytical MethodsProtein BiochemistryElectrostatics In BiomoleculesIon-exchange ChromatographyProtein BindingProtein CharacterizationProtein StructureProtein-ligand BindingIon Binding In BiomoleculesIon-exchange ResinsProtein ElectrostaticsProtein-ligand Electrostatics
Protein dynamic binding capacities on ion exchange resins are typically expected to decrease with increasing conductivity and decreasing protein charge. There are, however, conditions where capacity increases with increasing conductivity and decreasing protein charge. Capacity measurements on two different commercial ion exchange resins with three different monoclonal antibodies at various pH and conductivities exhibited two domains. In the first domain, the capacity unexpectedly increased with increasing conductivity and decreasing protein charge. The second domain exhibited traditional behavior. A mechanism to explain the first domain is postulated; proteins initially bind to the outer pore regions and electrostatically hinder subsequent protein transport. Such a mechanism is supported by protein capacity and confocal microscopy studies whose results suggest how knowledge of the two types of IEX behavior can be leveraged in optimizing resins and processes.
37