Molecular Therapy · 2002 · 108 citations · 41 references
Life SciencesMolecular BiologyGene TherapyMolecular VirologyVirologyBioanalytical Method ValidationPolymerase Chain ReactionAdeno-associated Viral VectorsAdenoviral VectorsAdenovirus VectorsCell LysisReal-time Polymerase Chain Reaction (Pcr)Sample LysisVector TiteringViral Lysis
Despite the clinical application of adeno-associated virus (AAV) gene therapy, the titration of viral stocks has not yet been standardized. This complicates the comparison of viral stocks between laboratories. Functional titering of AAV is time-consuming, requires the manipulation of hazardous material, and often has a high degree of variability. We established an optimized real-time quantitative polymerase chain reaction (RQ-PCR) titration assay to determine viral titers and compared it with a functional green fluorescent protein (GFP)-based titration method. With a combination of improved lysis procedures and RQ-PCR protocols we could decrease the intraexperimental coefficient of variation (CV) from 0.24±0.03 to 0.042±0.004 and the interexperimental CV from 0.34±0.06 to 0.093±0.028 following functional and RQPCR-based titration, respectively. This low variability conforms to even the strictest quality standards required, for example, in clinical laboratories. The highly standardized titration by RQPCR described here will be especially advantageous for groups working on AAV-based gene therapy in a good manufacturing practice setting. Despite the clinical application of adeno-associated virus (AAV) gene therapy, the titration of viral stocks has not yet been standardized. This complicates the comparison of viral stocks between laboratories. Functional titering of AAV is time-consuming, requires the manipulation of hazardous material, and often has a high degree of variability. We established an optimized real-time quantitative polymerase chain reaction (RQ-PCR) titration assay to determine viral titers and compared it with a functional green fluorescent protein (GFP)-based titration method. With a combination of improved lysis procedures and RQ-PCR protocols we could decrease the intraexperimental coefficient of variation (CV) from 0.24±0.03 to 0.042±0.004 and the interexperimental CV from 0.34±0.06 to 0.093±0.028 following functional and RQPCR-based titration, respectively. This low variability conforms to even the strictest quality standards required, for example, in clinical laboratories. The highly standardized titration by RQPCR described here will be especially advantageous for groups working on AAV-based gene therapy in a good manufacturing practice setting.
41
Chris Heid, Junko Stevens, Kenneth J. Livak et al. · Genome Research · 1996 · 6.2K citations · Full text
A novel method for real time quantitative RT-PCR.
U E Gibson, Chris Heid, P. Mickey Williams · Genome Research · 1996 · 2.1K citations · Full text
Kenneth J. Livak, Samantha Flood, J Marmaro et al. · Genome Research · 1995 · 1.6K citations · Full text