Canadian Journal of Civil Engineering · 1996 · 139 citations · 6 references
EngineeringCivil EngineeringEarthquake EngineeringSeismic DesignStructural EngineeringSeismic Design PrinciplesSteel Seismic DesignSteel StructuresStructural DesignStructural MechanicsStructural SystemsBeam-column ConnectionsBraced FramesColumn Base ConnectionsSeismic Code ProvisionsSeismic Design EarthquakeSteel Bracing SystemsSteel Frame StructuresSteel Moment Frames
Past and current seismic design provisions for steel structures in Japan are presented and compared with Canadian requirements. The performance of steel framed structures during the January 17, 1995, Hyogo-ken Nanbu earthquake is described. Numerous failures and examples of inadequate behaviour could be observed in buildings of various ages, sizes, and heights, and braced with different structural systems. In moment resisting frames, the damage included failures of beams, columns, beam-to-column connections, and column bases. Fracture of bracing members or their connections was found in concentrically braced frames. The adequacy of the current Canadian seismic design provisions is examined in view of the observations made. Key words: earthquake, seismic design, steel structures.
6
4. Near‐Source Ground Motion and its Effects on Flexible Buildings
John F. Hall, Thomas H. Heaton, Marvin W. Halling et al. · Earthquake Spectra · 1995 · 764 citations