Standard Shewhart control charts use fixed sample sizes at equal sampling intervals. The study proposes varying sample size based on the process mean to reduce detection time and demonstrates a fast initial response with two discrete manufacturing examples. The authors compare an adaptive‑sample‑size chart to a fixed‑sample‑size chart using average run length under variable magnitude mean shifts, illustrating the approach with two discrete manufacturing examples. Adaptive‑sample‑size charts yield significant improvements, especially for small shifts, without increasing in‑control average sample size, as shown in two discrete manufacturing examples.

Abstract

Abstract Standard Shewhart control charts employ fixed sample sizes at equal sampling intervals. By varying the sample size depending on the current location of the process mean, the mean time to detect an off-target condition can be reduced. The adaptive-sample-size control chart is compared with the fixed-sample-size control chart in terms of average run length under shifts in the process mean of variable magnitude. Significant improvements have been obtained with the adaptive-sample-size charts, particularly for small shifts. These improvements are achieved without increasing the in-control average sample size beyond that of the fixed-sample-size approach. A fast initial response is suggested and advantages of the procedure over fixed-sample-size control are illustrated with two examples from discrete manufacturing processes.