Determination of Bisphenol A in Receipts and Carbon Paper by HPLC-UV

Andy Dang, Monita Sieng, Joseph J. Pesek, Maria T. Matyska

Journal of Liquid Chromatography & Related Technologies · 2014 · 23 citations · 11 references

Concepts

Abstract

Abstract A simple and efficient method for determination of Bisphenol A (BPA), an endocrine disrupting chemical (EDC), is developed without the requirement of derivatization. Due to the prevalence of exposure of BPA-containing products to the general public, high-quality testing and monitoring methods are essential. BPA was separated and quantified under reverse-phase conditions using a high-performance liquid chromatography/ultraviolet absorption (HPLC-UV) detection method. A silica hydride-based C8 column along with an effective gradient protocol yielded well-resolved peaks that allowed for the direct analyses of BPA in receipt paper and carbon copies of lab notebooks. Excellent linear correlation was observed (R2 = 0.9936) in the calibration curve obtained from the HPLC-UV analyses. Keywords: Bidentate C8 HPLC columncarbon copiesBisphenol A (BPA)BPA determinationBPA in receiptsHPLC-UVsilica hydride stationary phase

References

11