International Journal of Communication Systems · 2005 · 50 citations · 15 references
ComputingComputer EngineeringComputer ScienceComputer NetworksInterconnection NetworksReal-time SystemsCommunication NetworksIndustrial Communication NetworksIndustrial NetworkingNetwork ArchitectureNetwork Performance AnalysisPacket SwitchingConstraintsEnd-to-end DelayEnd-to-end Delay AnalysisEthernetNetwork CalculusReal-time EthernetReal-time Industrial CommunicationReal-time Networking
Ethernet is increasingly used to interconnect industrial devices. This study examines the performance of switched Ethernet networks for real‑time industrial communications. The authors model a switched Ethernet as a sequence of elementary components, aggregate component temporal properties from Cruz’s survey, derive a global formula for maximum end‑to‑end delay, and use it to determine limits on the number of I/O cards and message sizes. © 2005 John Wiley & Sons, Ltd.
The Ethernet network is more and more used to interconnect industrial devices. The objective of this paper is to study the performances of such a network to support real-time communications. For this, first we propose a general representation to model a switched Ethernet network by using a sequence of elementary components such as buffers, multiplexers, etc. Second, we aggregate the individual temporal properties of each component given in the Cruz' survey to obtain a global formula enabling one to calculate the maximum end-to-end delay for any industrial communication scenarios. Finally, we deduce the limits of the switched Ethernet network regarding the number of input/output cards connected to the network and to the sizes of periodic and aperiodic messages. Copyright © 2005 John Wiley & Sons, Ltd.
15