Identification of TSC peaks and surface-voltage stability in Teflon FEP

Heinz von Seggern

Journal of Applied Physics · 1979 · 89 citations · 16 references

Concepts

Abstract

In this paper we examine the stability of corona- and electron-beam-charged 25-μm FEP-A in open circuit by using thermally stimulated (TSC) measurements. We show that electrets charged with electron beams of 10 keV or higher are more stable than corona-charged foils. The inferior stability of corona-charged samples is due to the filling of surface traps as opposed to volume traps in electron-beam-charged samples. A peak at 155 °C was attributed to surface traps located at a depth of 0–0.5 μm, while a peak at 170 °C is due to charge stored 0.5–1.8 μm beneath the nonmetallized surface. The volume traps yield a peak at 200 °C. The total volume trap density was estimated to 1.4×1014 traps/cm3.

References

16