Publication | Open Access
Single-Arm Evaluation of the AccuCirc Device for Early Infant Male Circumcision in Botswana
16
Citations
20
References
2014
Year
Obstetric SurgerySterile Accucirc KitProgrammatic EimcMedicinePediatricsMaternal HealthOperative Vaginal DeliveryNewborn MedicineSurgeryFetal DistressObstetricsCaesarean SectionMedical DevicesSingle-arm EvaluationAccucirc Device
: Existing devices for early infant male circumcision (EIMC) have inherent limitations. We evaluated the newly developed AccuCirc device by circumcising 151 clinically well, full-term male infants with birth weight ≥2.5 kg within the first 10 days of life from a convenience sample in 2 hospitals in Botswana. No major adverse events were observed. There was 1 local infection, 5 cases of minor bleeding, and 1 case of moderate bleeding. In 3 cases, the device made only partial incisions that were completed immediately by the provider without complications. Parental satisfaction was high: >96% of mothers stated that they would circumcise a future son. The pre-assembled, sterile AccuCirc kit has the potential to overcome obstacles related to supply chain management and on-site instrument disinfection that can pose challenges in resource-limited settings. In our study, the AccuCirc was safe and it should be considered for programmatic EIMC in resource-limited settings.
| Year | Citations | |
|---|---|---|
Page 1
Page 1