Arthroscopy The Journal of Arthroscopic and Related Surgery · 1997 · 117 citations · 14 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBone GraftingOrthopedic BiomechanicsOrthopedicsFixation BiomechanicsKnee BiomechanicsLigament InjuriesLigament ReconstructionTendon ReconstructionTendon RepairBiomechanics Of Ligament ReconstructionCruciate Ligament SurgeryInterference Screw MaterialsKnee Ligament ReconstructionPatellar Tendon ReconstructionSurgical Reconstruction BiomechanicsTendon Graft Fixation
This investigation compared the maximum load at failure of BioScrew (Linvatec Corp, Largo, FL) and titanium alloy interference screw femoral fixation using a human cadaveric model that approximated the anatomical orientation and physiological strain rate of in vivo bone-patellar tendon-bone (BPTB) graft loading following anterior cruciate ligament reconstruction. Eighteen fresh-frozen human BPTB allografts (10-mm wide, 10-mm thick, 25-mm long bone plugs) with either BioScrew or titanium alloy (Ti 6A14V) screw (7 x 25 mm) fixation were compared for maximum load at failure at a strain rate of 20 mm/minute. Nine cadaver femurs with bone mineral densities of 0.88 +/- 0.18 g/cm2 (anterior/posterior) and 1.3 +/- 0.24 g/cm2 (lateral) received the allografts. No statistical differences were observed in maximum load at failure (P = .95) or failure mode (P = .11) between specimens fixed with either screw type. When biomechanically tested with anatomic orientation and at functionally relevant strain rates, the BioScrew provided maximum load at failure equal to a titanium alloy screw.
14
Effects of Bone Mineral Density on Pedicle Screw Fixation
Thomas L. Halvorson, Lee Ann Kelley, Kevin A. Thomas et al. · Spine · 1994 · 647 citations