Comparison of Atmospheric‐Pressure Plasma versus Low‐Pressure RF Plasma for Surface Functionalization of PTFE for Biomedical Applications

Christian Sarra‐Bournet, Stéphane Turgeon, Diego Mantovani, Gaétan Laroche

Plasma Processes and Polymers · 2006 · 67 citations · 36 references

Concepts

Abstract

Abstract Summary: PTFE surface modifications have been realized using low‐pressure RFGD, DBD and APGD in different atmospheres. Compared to the RFGD NH 3 plasma, the DBDs operating in H 2 /N 2 lead to similar surface concentrations of amino groups and similar surface damage, but with a much higher specificity. Both APGDs in H 2 /N 2 and NH 3 /N 2 lead to lower concentrations of amino groups, but with similar specificity, and with lower surface damage than the RFGD treatment. A method is proposed to evaluate the efficiency of the different discharges for amine surface functionalization of PTFE, and it is concluded that the NH 3 /N 2 APGD discharge is the one that give the best results for an effective surface treatment. Experimental setups for the DBD and the APGD plasma systems. magnified image Experimental setups for the DBD and the APGD plasma systems.

References

36