Annals of Plastic Surgery · 2006 · 35 citations · 30 references
MedicineDermatologySurgeryBiomedical OpticsBiophotonicsMicrosurgeryBiomedical Laser ApplicationsLaser OpticsLaser PhysicsLaser SurgeryLaser-tissue InteractionVascular Lesion TreatmentBeam Pulse DurationBeam Spot SizeLaser Pulse DurationLaser Therapy Of Vascular LesionsLasersPulse Duration EffectsPulsed Dye Laser TherapyTreatment Parameters
In Brief Modern lasers allow different parameters to be altered in an effort to gain further improvement in otherwise resistant capillary vascular malformations (CMs). The aim of this study was to examine the effect of changing the pulse duration, wavelength, spot size, and fluence on the color and capillary architecture of 585-nm pulsed-dye, laser-resistant CMs. Eighteen patients were assessed with a depth measurement videomicroscope (DMV) before and after 12 test patches with ScleroPlus and V-Beam lasers at specified parameters. In the majority of the test patch areas, there was little improvement after treatment. However, 44% of patients had greater than 75% clearance in at least 1 test patch site. This study demonstrates that both lasers can achieve further lightening in 585 nm 0.45 msec pulsed-dye laser-resistant CMs. However, in CMs consisting of small-diameter deep vessels, further improvement is unlikely. Eighteen patients with resistant capillary vascular malformations underwent test-patch evaluations with the Scleroplus and V-Beam lasers at specified parameters. Although most areas showed little improvement, 44% of patients demonstrated greater than 75% clearance in at least 1 test site.
30
Christine Dierickx, J. Michael Casparian, Vasan Venugopalan et al. · Journal of Investigative Dermatology · 1995 · 257 citations · Full text