Review of Scientific Instruments · 2013 · 18 citations · 6 references
Natural SciencesPhysicsElectromagneticsElectromagnetismPlasma PhysicsMagnetized PlasmaPlasma SimulationPlasma SourcesBeam Intensity Fluctuation AnalysisBeam Intensity OptimizationIon Beam ExtractionIon Source DesignIon Source PhysicsNegative Ion SourcesPositive Ion Sources
Non-uniformity of the negative ion beams in the JT-60 negative ion source with the world-largest ion extraction area was improved by modifying the magnetic filter in the source from the plasma grid (PG) filter to a tent-shaped filter. The magnetic design via electron trajectory calculation showed that the tent-shaped filter was expected to suppress the localization of the primary electrons emitted from the filaments and created uniform plasma with positive ions and atoms of the parent particles for the negative ions. By modifying the magnetic filter to the tent-shaped filter, the uniformity defined as the deviation from the averaged beam intensity was reduced from 14% of the PG filter to ∼10% without a reduction of the negative ion production.
6
Present status of the negative ion based NBI system for long pulse operation on JT-60U
Yoshitaka Ikeda, N. Umeda, N. Akino et al. · Nuclear Fusion · 2006 · 65 citations
Operation of the negative-ion based NBI for JT-60U
M. Kuriyama, N. Akino, T. Aoyagi et al. · Fusion Engineering and Design · 1998 · 36 citations
The origin of beam non-uniformity in a large Cs-seeded negative ion source
M. Hanada, T. Seki, N. Takado et al. · Nuclear Fusion · 2006 · 36 citations