Physics of Plasmas · 2001 · 103 citations · 6 references
Natural SciencesNuclear EngineeringMetrologyNuclear InstrumentationOpticsIgnition System DiagnosticsInterferometryLaser OpticsLaser PhysicsShock WavesUltrafast OpticsIgnition Timing TestingLaser IgnitionLaser InterferometryLaser-based DiagnosticsPulse Shape AnalysisShock IgnitionShock Measurement
Among the final shots at the Nova laser [Campbell et al., Rev. Sci. Instrum. 57, 2101 (1986)] was a series testing the VISAR (velocity interferometry system for any reflector) technique that will be the primary diagnostic for timing the shocks in a NIF (National Ignition Facility) ignition capsule. At Nova, the VISAR technique worked over the range of shock strengths and with the precision required for the NIF shock timing job—shock velocities in liquid D2 from 12 to 65 μm/ns with better than 2% accuracy. VISAR images showed stronger shocks overtaking weaker ones, which is the basis of the plan for setting the pulse shape for the NIF ignition campaign. The technique is so precise that VISAR measurements may also play a role in certifying beam-to-beam and shot-to-shot repeatability of NIF laser pulses.
6
Shock-Induced Transformation of Liquid Deuterium into a Metallic Fluid
P. M. Celliers, G. W. Collins, L. B. Da Silva et al. · Physical Review Letters · 2000 · 215 citations
Natural Sciences, Physics, Optics +15
Nova experimental facility (invited)
E. M. Campbell, John T. Hunt, Erlan S. Bliss et al. · Review of Scientific Instruments · 1986 · 159 citations