Occupational and Environmental Medicine · 1988 · 168 citations · 19 references
PharmacyEnvironmental SciencesToxicologyOccupational HealthOccupational ToxicologyRadiation DosimetryExposure AssessmentHeavy Metal Risk AssessmentLead ExposureLead ToxicologyOccupational Heavy Metal ExposureOccupational Radiation ProtectionBlood Lead Level AssessmentCumulative ExposureCumulative Exposure AssessmentLead Exposure BiomonitoringLead Exposure RiskOccupational Lead ExposureX-ray Fluorescence Detection
In vivo tibia lead measurements of 20 non-occupationally exposed and 190 occupationally exposed people drawn from three factories were made using a non-invasive x ray fluorescence technique in which characteristic x rays from lead are excited by gamma rays from a cadmium-109 source. The maximum skin dose to a small region of the shin was 0.45 mSv. The relation between tibia lead and blood lead was weak in workers from one factory (r = 0.11, p greater than 0.6) and among the non-occupationally exposed subjects (r = 0.07, p greater than 0.7); however, a stronger relation was observed in the other two factories (r = 0.45, p less than 0.0001 and r = 0.53, p less than 0.0001). Correlation coefficients between tibia lead and duration of employment were consistently higher at all three factories respectively (r = 0.86, p less than 0.0001; r = 0.61, p less than 0.0001; r = 0.80, p less than 0.0001). A strong relation was observed between tibia lead and a simple, time integrated, blood lead index among workers from the two factories from which blood lead histories were available. The regression equation from two groups of workers (n = 88, 79) did not significantly differ despite different exposure conditions. The correlation coefficient for the combined data set (n = 167) was 0.84 (p less than 0.0001). This shows clearly that tibia lead, measured in vivo by x-ray fluorescence, provides a good indicator of long term exposure to lead as assessed by a cumulative blood lead index.
19
A comparison of concentrations of lead in human tissues.
P.S.I. Barry · Occupational and Environmental Medicine · 1975 · 503 citations · Full text
Pharmacy, Anatomy, Toxicology +16
Studies of the Inferior Vena Cava in Late Pregnancy
M. G. Kerr, D. B. Scott, Erica A. Samuel · BMJ · 1964 · 361 citations · Full text
Medicine, Gynecology, Obstetrics +7
X-ray fluorescence analysis of lead in human skeleton in vivo.
L. Ahlgren, K. Lidén, Sören Mattsson et al. · Scandinavian Journal of Work Environment & Health · 1976 · 155 citations · Full text
Pharmacy, Chemistry, Toxicology +13