EngineeringBiomedical EngineeringBioinstrumentationBiomemsSensorsLevel MeasurementOptical SensorsPressure MeasurementPressure SensorsTemperature SensorsFiber Bragg Grating SensorsFiber Bragg GratingsHydrostatic Level MeasurementHydrostatic PressureHydrostatic Pressure MeasurementPressure SensingPressure SensitivityTemperature Sensitivity
Abstract Pressure and temperature are two important parameters in hydrostatic pressure based liquid level sensing. In this study, we propose a liquid level sensor based on hydrostatic pressure variation sensed by fiber Bragg grating (FBG1) attached to a bourdon tube. The water column pressure sensitivity coefficient of FBG1 is 0.072 nm/m. One more FBG2 is incorporated to avoid cross sensitivity of temperature. The temperature sensitivity coefficient of the FBG1 and FBG2 are 10.5 pm/°C and 10.2 pm/°C. The packaged sensor head can be placed inside a chamber and also easily mountable external to the tank for the measurement of liquid level. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:1679–1683, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26890