Analytical Chemistry · 2013 · 24 citations · 20 references
PharmacyMolecular BiologyPharmacologyApoptosisBiochemical PharmacologyProteomicsAffinity ChromatographyBiomarker AnalysisBiomarker DevelopmentDeath ReceptorsPeptide AnalysisProteomic BiomarkersAbsolute Protein QuantificationAbsolute QuantificationImmobilized Metal Affinity ChromatographyInternal StandardsLower Limit Of QuantificationMethionine OxidationProtein Biomarker QuantificationTargeted Quantification
The major challenge in targeted protein quantification by LC-MS/MS in serum lies in the complexity of the biological matrix with regard to the wide diversity of proteins and their extremely large dynamic concentration range. In this study, an LC-MS/MS method was developed for the simultaneous quantification of the 60-kDa biopharmaceutical proteins recombinant human tumor necrosis factor-related apoptosis-inducing ligand wild type (rhTRAIL(WT)) and its death receptor 4 (DR4)-specific variant rhTRAIL(4C7) in human and mouse serum. Selective enrichment of TRAIL was accomplished by immobilized metal affinity chromatography (IMAC), which was followed by tryptic digestion of the enriched sample and quantification of a suitable signature peptide. For absolute quantification, (15)N-metabolically labeled internal standards of rhTRAIL(WT) and rhTRAIL(4C7) were used. Since the signature peptides that provided the highest sensitivity and allowed discrimination between rhTRAIL(WT) and rhTRAIL(4C7) contained methionine residues, we oxidized these quantitatively to their sulfoxides by the addition of 0.25% (w/w) hydrogen peroxide. The final method has a lower limit of quantification of 20 ng/mL (ca. 350 pM) and was fully validated according to current international guidelines for bioanalysis. To show the applicability of the LC-MS/MS method for pharmacokinetic studies, we quantified rhTRAIL(WT) and rhTRAIL(4C7) simultaneously in serum from mice injected intraperitoneally at a dose of 5 mg/kg for each protein. This is the first time that two variants of rhTRAIL differing by only a few amino acids have been analyzed simultaneously in serum, an approach that is not possible by conventional enzyme-linked immuno-sorbent assay (ELISA) analysis.
20
Safety and antitumor activity of recombinant soluble Apo2 ligand
Avi Ashkenazi, Roger Pai, Sharon Fong et al. · Journal of Clinical Investigation · 1999 · 2.2K citations · Full text
Medicine, Oncology, Pharmacology +17
Selected reaction monitoring for quantitative proteomics: a tutorial
Vinzenz Lange, Paola Picotti, Bruno Domon et al. · Molecular Systems Biology · 2008 · 1.4K citations · Full text
Jun X. Yan, Robin Wait, Tom Berkelman et al. · Electrophoresis · 2000 · 705 citations