Off-resonance transformer charging for 250-kV water blumlein

E.G. Cook, L.L. Reginato

IEEE Transactions on Electron Devices · 1979 · 13 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

An off-resonance transformer for charging a 250-kV Blumlein system provides a viable alternative to other charging schemes by permitting the use of conventional thyratrons. Such a transformer must have reliability, a reasonable voltage stepup, and a nonreversing primary current. This paper presents the analysis, design, and performance data for such a transformer. The strong interrelationship between transformer design and Blumlein requirements necessitates that Blumlein description and design criterion be briefly presented prior to transformer design such that transformer load requirements be defined.