Proceedings of the National Academy of Sciences · 1988 · 162 citations · 5 references
Natural SciencesBiophysicsPhysiologyMagnetic Resonance BiophysicsSpectroscopic AnalysisSpectroscopyCardiac PhysiologyElectron Paramagnetic ResonanceElectron Spin Resonance SpectroscopyMagnetic Resonance SpectroscopyMicrowave SpectroscopyBiological Electron Spin ResonanceContractile Function AssessmentFree Radical DetectionFree Radical KineticsHigh-frequency Electron Paramagnetic ResonanceMyocardial Oxygen ConsumptionOxygen Consumption KineticsSpectrometer Design
Free radicals are hypothesized to mediate disease across tissues, yet EPR spectroscopy has been unable to measure them in situ because conventional spectrometers cannot probe whole organs. The authors developed an EPR spectrometer optimized for measuring free radicals in intact biological organs or tissues. The system uses a 1–2 GHz microwave bridge with a source locked to a recessed gap loop‑gap resonator, enabling real‑time measurement of free radicals and cardiac contractile function in isolated beating hearts and allowing kinetic studies of radical uptake and metabolism in perfused and ischemic hearts. The spectrometer detects radical concentrations as low as 0.4 µM, permits noninvasive measurement of tissue oxygen consumption, and demonstrates that EPR can directly assess in vivo free‑radical metabolism and oxygen use, offering promise for studying radical generation effects on whole tissues.
Free radicals have been hypothesized to be important mediators of disease in a variety of organs and tissues. Electron paramagnetic resonance (EPR) spectroscopy can be applied to directly measure free radicals; however, it has not been possible to measure important biological radicals in situ because conventional spectrometer designs are not suitable for the performance of measurements on whole organs or tissues. We report the development of an EPR spectrometer designed for optimum performance in measuring free radicals in intact biological organs or tissues. This spectrometer consists of a 1- to 2-GHz microwave bridge with the source locked to the resonant frequency of a recessed gap loop-gap resonator. With this spectrometer, radical concentrations as low as 0.4 microM can be measured. Isolated beating hearts were studied in which simultaneous real time measurements of free radicals and cardiac contractile function were performed. This in vivo EPR technique was applied to study the kinetics of free radical uptake and metabolism in normally perfused and globally ischemic hearts. In addition, we show that this technique can be used to noninvasively measure tissue oxygen consumption. Thus, it is demonstrated that EPR spectroscopy can be applied to directly measure in vivo free radical metabolism and tissue oxygen consumption. This technique offers great promise in the study of in vivo free radical generation and the effects of this radical generation on whole biological tissues.
5
Control of maximum rates of glycolysis in rat cardiac muscle.
K Kobayashi, J. R. Neely · Circulation Research · 1979 · 314 citations