K\ensuremath{\alpha} absorption spectroscopy has been used to diagnose the low-temperature, high-density region of layered targets (high-Z on low-Z elements) irradiated by 0.26-\ensuremath{\mu}m laser light at irradiances between 2\ifmmode\times\else\texttimes\fi{}${10}^{14}$ and 4\ifmmode\times\else\texttimes\fi{}${10}^{15}$ W/${\mathrm{cm}}^{2}$. Time-resolved and time-integrated spectra have been recorded from the front and the rear of the target with high spectral resolution in the 1--3-keV range and low spectral resolution in the 40-eV--4-keV range. Experimental results provide measurements of the electron-temperature gradient shape in the region 50--200 eV. A detailed analysis of the atomic structure of He-like to F-like ions of chlorine and aluminum has been performed to give simulated absorption spectra as a function of plasma parameters. We show here a measurement of the shallow electron-temperature gradient around 100 eV built up by the absorption of x rays emitted by the laser-irradiated high-Z layer. This is in very good agreement with results obtained from a one-dimensional hydrocode including photon transport physics.