<title>Direct laser beam diagnostics</title>

Jan van Gilse, Stanley Koczera, Daniel F. Greby

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 1991 · 11 citations · 0 references

Concepts

Abstract

Increasing use is being made of high-power laser plant to cut, weld, harden, coat and alloy metals. Diagnostic systems analyzing the focused and unfocused laser beam are essential for advanced development and operation of such high-power laser plant. The paper presents various technical options for diagnosing high-power laser beams, with particular attention to a measuring technique which enables focused and unfocused beams to be diagnosed at beam powers of more than 20 kW and intensities of more than 10 7 W/cm2. Laser-beam diagnostics support 3D graphic displays of the laser beam intensity distribution. These graphics indicate the beam position, beam radius and beam intensity. Beam-descriptive parameters such as the M2 quality factor or the Rayleigh length can also be determined.