The Astrophysical Journal · 1997 · 66 citations · 16 references
Natural SciencesAstronomyPhysicsAstrophysicsPlasma PhysicsSpectroscopyAstrophysical PlasmasPlasma AstrophysicsPlasma DiagnosticsStellar SpectroscopyX-ray SpectroscopyAstrophysical Plasma DiagnosticsElectron Energy Distribution FunctionEmission-line DiagnosticsGas IonizationIonizationIonization ParameterSpectral CharacterizationStellar Flares
We present laboratory measurements of high-resolution spectra of iron Kα emission under transient ionization conditions similar to those that are believed to exist in stellar flares and young supernova remnants. Taking advantage of our high spectral resolution (λ/Δλ ≥ 2000), we identify a number of transitions that can serve as diagnostics of ionizing plasmas. By varying the excitation energy in the experiments, we constrain the effects of the electron distribution on these diagnostic lines. Using our measured line ratios, we deduce values for the ionization time, η = Net, in the plasma, which agree with the actual values to ~20% accuracy. This result gives us confidence to our ability to derive similar constraints on astrophysical plasmas from remote X-ray spectroscopic observations.
16
The Electron Beam Ion Trap: A New Instrument for Atomic Physics Measurements
Morton A. Levine, R. E. Marrs, J. Henderson et al. · Physica Scripta · 1988 · 472 citations
UV and X-ray spectroscopy of astrophysical and laboratory plasmas
Kazuya Yamashita, Takayuki Watanabe · 1996 · 276 citations
Natural Sciences, Astronomy, Physics +14