Review of Scientific Instruments · 1999 · 19 citations · 4 references
Natural SciencesNuclear EngineeringPhysicsNuclear PhysicsPlasma PhysicsSpectroscopyNeutron DetectionNeutron Spectrum AnalysisNuclear SpectroscopyPlasma DiagnosticsRadiation SpectroscopyFull Width At Half MaximumNeutron DiagnosticsNeutron Energy SpectrumNeutron SpectrometryNeutron SpectroscopyNeutron Spectrum CharacterizationResponse Function CalculationTotal Efficiency
A 14 MeV neutron spectrometer, based on the principle of the proton recoil telescope, has been installed as a deuterium–tritium (DT) plasma diagnostic at the Joint European Torus. The device comprises three identical telescope modules arranged one behind the other, to increase efficiency without worsening resolution. It views the plasma along a horizontal line of sight. The total efficiency is 7.05×10−5 counts per (neutron per cm2), and the calculated response function has a full width at half maximum of 2.2% at an incident neutron energy of 14.1 MeV. The spectrometer was operational throughout the recent DT experiment No. 1, and selected neutron spectra have been analyzed in terms of the contributions from the various neutron production mechanisms.
4
Fusion neutron energies and spectra
Henry Brysk · Plasma Physics · 1973 · 410 citations
Simulations of deuterium-tritium experiments in TFTR
R. Budny, Michael G.H. Bell, H. Biglari et al. · Nuclear Fusion · 1992 · 171 citations