Stroke · 2008 · 221 citations · 27 references
MedicineNeurologyRadiologyBiomedical ImagingDiagnostic ImagingNeuroradiologyBrain ImagingCerebral Blood FlowCerebrovascular DiseaseCerebrovascular ImagingMagnetic Resonance ImagingVascular ImagingArterial Spin LabelingBlood Oxygenation Level-dependent ContrastBlood Oxygenation Level-dependent ImagingCerebral Blood Flow AlterationsCerebral Blood Flow QuantificationCerebral Blood Flow RegulationCerebral Metabolic RateRegional Cerebral Blood Flow
BACKGROUND AND PURPOSE: Blood oxygen level-dependent MRI (BOLD MRI) of hypercapnia-induced changes in cerebral blood flow is an emerging technique for mapping cerebrovascular reactivity (CVR). BOLD MRI signal reflects cerebral blood flow, but also depends on cerebral blood volume, cerebral metabolic rate, arterial oxygenation, and hematocrit. The purpose of this study was to determine whether, in patients with stenoocclusive disease, the BOLD MRI signal response to hypercapnia is directly related to changes in cerebral blood flow. METHODS: Thirty-eight patients with stenoocclusive disease underwent mapping of CVR by both BOLD MRI and arterial spin labeling MRI. The latter technique was used as a reference standard for measurement of cerebral blood flow changes. RESULTS: Hemispheric CVR measured by BOLD MRI was significantly correlated with that measured by arterial spin labeling MRI for both gray matter (R=0.83, P<0.0001) and white matter (R=0.80, P<0.0001). Diagnostic accuracy (area under receiver operating characteristic curve) for BOLD MRI discrimination between normal and abnormal hemispheric CVR was 0.90 (95% CI=0.81 to 0.98; P<0.001) for gray matter and 0.82 (95% CI=0.70 to 0.94; P<0.001) for white matter. Regions of paradoxical CVR on BOLD MRI had a moderate predictive value (14 of 19 hemispheres) for spatially corresponding paradoxical CVR on arterial spin labeling MRI. Complete absence of paradoxical CVR on BOLD MRI had a high predictive value (31 of 31 hemispheres) for corresponding nonparadoxical CVR on arterial spin labeling MRI. CONCLUSIONS: Arterial spin labeling MRI confirms that, even in patients with stenoocclusive disease, the BOLD MRI signal response to hypercapnia predominantly reflects changes in cerebral blood flow.
27
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Satoshi Ogawa, T M Lee, A R Kay et al. · Proceedings of the National Academy of Sciences · 1990 · 6.5K citations · Full text
Medicine, Neuroscience, Radiology +17
Brain magnetic resonance imaging with contrast-dependent oxygenation
Seigo Ogawa · Medical Entomology and Zoology · 1990 · 1.4K citations
Medicine, Neuroscience, Radiology +14