Medical Physics · 2007 · 18 citations · 10 references
MedicineRadiation OncologyRadiation DosimetryRadiation TransportTreatment PlanningAbsorbed DoseExternal Beam DosimetryExternal Beam RadiotherapyPatient-specific DosimetryProton DosimetryProton TherapyBeam Delivery SystemsBragg Peak FormationConformalityExternal Beam Dose DistributionPassive ScatteringProton Dose DistributionProton Therapy DosimetrySpread-out Bragg Peak Dosimetry
A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how the SOBP is generated and will explore the tolerances of the various components and their subsequent effect on the dose distribution. A specific aspect of this investigation includes a case study involving the use of a beam current modulated system. In such a system, the intensity of the beam current can be varied in synchronization with the revolution of the range-modulator wheel. As a result, the weights of the pulled-back Bragg peaks can be individually controlled to produce uniform dose plateaus for a large range of treatment depths using only a small number of modulator wheels.
10
Spot scanning system for proton radiotherapy
Tatsuaki Kanai, Kiyomitsu Kawachi, Y Kumamoto et al. · Medical Physics · 1980 · 189 citations
Medicine, Radiation Oncology, Clinical Radiation Oncology +14