Measurement of Pressure and Density Inside a Single Sonoluminescing Bubble

David J. Flannigan, Stephen D. Hopkins, Carlos G. Camara, Seth Putterman, Kenneth S. Suslick

Physical Review Letters · 2006 · 90 citations · 30 references

Concepts

Abstract

The average pressure inside a sonoluminescing bubble in sulfuric acid has been determined by two independent techniques: (1) plasma diagnostics applied to Ar atom emission lines, and (2) light scattering measurements of bubble radius vs time. For dimly luminescing bubbles, both methods yield intracavity pressures approximately 1500 bar. Upon stronger acoustic driving of the bubble, the sonoluminescence intensity increases 10,000-fold, spectral lines are no longer resolved, and radius vs time measurements yield internal pressures > 3700 bar. Implications for a hot inner core are discussed.

References

30