International Journal of Environmental Studies · 2002 · 14 citations · 6 references
EngineeringChemical EngineeringEnvironmental EngineeringColloid ScienceWastewater TreatmentWater TreatmentIron HydroxidesIron OxidesMagnetic OxidesMagnetism Of Inorganic CompoundsWastewater BiotreatmentWastewater ManagementCoagulationColloid CoagulationColloid-surface InteractionsMagnetiteSettlingSettling TimeSettling VelocityTreatment Efficiency
The feasibility of treating direct dye wastewater by coagulation is investigated herein. The theoretical development of colloid interactions for coagulation is also reviewed. Ferric chloride and its combination with hydrated lime [Ca(OH) 2 ] is used as a coagulant. Treatment for high strength dye wastewater is preferred and better than medium strength wastewater which showed slow settling velocity and long settling time. The effect of magnetic powder on ferric chloride coagulation system reveals an obvious improvement in settling, particularly for medium strength direct dye wastewater. In addition, increasing magnetite (Fe 3 O 4 ) dosages enhances the treatment efficiency of settling.
6
Principles of colloid and surface chemistry
Egon Matijević · Journal of Colloid and Interface Science · 1979 · 2.8K citations
Sewage Clarification with Magnetite Particles
N. A. Booker, David Keir, A. J. Priestley et al. · Water Science & Technology · 1991 · 81 citations
Engineering, Environmental Engineering, Environmental Sciences +17
Treatment of wastewaters from dye industry
N. Koprivanac, Goran Bosanac, Zorana Grabarić et al. · Environmental Technology · 1993 · 49 citations
Engineering, Chemical Engineering, Environmental Engineering +17