New Phytologist · 1967 · 10 citations · 5 references
Life SciencesBotanyPlant SciencesPhysiological EcologyPlant EcophysiologyPlant PhysiologyStomatal PhysiologyWater ContentWater LossWater RelationsWater TransportLeaf Water Potential MeasurementPlant Water BalancePlant Water PotentialPlant Water Status EstimationWater Loss PhysiologyWater Stress PhysiologyWater UptakeWater Uptake By Plants
S ummary A simplified modification of the micro‐osmometer of Macklon and Weatherley (1965 a ) for the determination of depressions of water‐potential in leaves, Δ W (DPD), is described. The apparent minimum Δ W of 3 1 / 2 atm for non‐transpiring water‐culture plants of Ricinus communis reported by Tinklin and Weatherley (1966) is considered further. Evidence is provided that this is in fact a zero value, the level recorded being due to the errors induced by water loss on sampling and by water uptake by continued growth of tissue during determinations. However, a simple subtraction of 3 1 / 2 atm from all Δ W values is not proposed as there are indications that a threshold AH’may exist above which continued growth does not occur, so that higher Δ W records will approach more closely the true value.
5