Reproducibility of the 13C-Octanoic Acid Breath Test for Assessment of Gastric Emptying in Healthy Preterm Infants

Christopher Barnett, Antonie Snel, Taher Omari, Geoff Davidson, Ross Haslam, Ross N. Butler

Journal of Pediatric Gastroenterology and Nutrition · 1999 · 55 citations · 19 references

Concepts

Abstract

BACKGROUND: The 13C-octanoic acid breath test has been used to measure gastric emptying in preterm infants, but the reproducibility of the test has not been evaluated in this population. METHODS: Fifty-six paired breath test analyses were performed on 28 healthy preterm infants 1 to 5 days apart using the same food type, volume, and energy content for each paired sample. Breath samples were taken before the feeding, at 5-minute intervals after feeding for 30 minutes, then each 15 minutes for 4 hours. Samples were analyzed using an isotope-ratio mass spectrometer, and 3C recovery was used to calculate values for gastric-emptying coefficient and gastric half-emptying time. RESULTS: There was no significant difference between test results on different days in the paired samples studied. gastric-emptying coefficients for the first and subsequent samples were 2.6+/-0.1 (mean+/-SEM) and 2.7+/-0.1, respectively, and half-emptying times were 44.5+/-3.7 minutes and 41.4+/-3.2 minutes. CONCLUSION: The 13C-octanoic acid breath test is a reliable, noninvasive, and reproducible measure of gastric emptying in preterm infants that should have wide application for use in this population.