Fractionation of a Light Crude Oil and Identification and Quantitation of Aliphatic, Aromatic, and Biomarker Compounds by GC-FID and GC-MS, Part I

Z. Wang, Merv Fingas, K. Li

Journal of Chromatographic Science · 1994 · 249 citations · 1 references

Concepts

Abstract

A rapid, reliable, and effective method is developed for the fractionation of oil into aliphatic and aromatic hydrocarbons using a 3-g silica gel micro glass chromatographic column. A standard mixture, composed of 15 aliphatic n-alkanes and 16 target polycyclic aromatic hydrocarbons, is used to develop the silica gel chromatographic column separation procedure and to determine the collection points for the various fractions. The recoveries for aliphatic and aromatic hydrocarbons in the standard mixture are in the range of 95–103% with relative standard deviations under 4%. This procedure yields very clean separation for a light crude oil (Alberta Sweet Mix Blend [ASMB]) and other oils. Up to 50 mg ASMB oil can be quantitatively fractionated into aliphatic and aromatic fractions using 3 g silica gel. The resulting fractions are analyzed by capillary gas chromatography coupled with flame-ionization detection and gas chromatography-mass spectrometry.

References

1