Journal of Applied Physics · 1981 · 31 citations · 4 references
EngineeringMaterials EngineeringMaterials ScienceComputational Materials ScienceMagnetic MaterialsNuclear MaterialsIon ImplantationMagnetic Materials SimulationStrain AnalysisStrain EngineeringStrain HardeningBiomedical ImplantsDensityDensity RatioIon Implantation EffectsIon Implantation SimulationProportionalityX-ray Diffraction AnalysisX-ray Diffraction Strain Analysis
The detailed properties of strain distributions in Ne+, B+, and He+ implanted magnetic bubble garnet materials are accounted for by calculating the nuclear energy loss as a function of depth. The calculation is based on stopped ion distributions for ZnS, with suitable corrections made for differences in material density. The constant of proportionality K between strain and nuclear energy loss, and the density ratio l are determined for each ion by comparing calculated strain distributions with experimental results obtained previously using an x-ray diffraction technique. It is found that K is roughly the same for all three ions, 0.016±0.003 (eV/Å3)−1, and that the average value l = 0.79±0.08 is consistent with the actual density ratio l = 0.72. Good agreement is found in additional examples of both single and multiple implants (±10% relative error). Finally, a procedure for selecting the incident energies and dosages required to produce a uniformly strained layer for bubble device applications is described, and then demonstrated by achieving a 0.4-um-thick layer with (1.07±0.09)% strain, using a double B+ implant.
4
Ion Implanted Patterns for Magnetic Bubble Propagation
R. Wolfe, J. C. North, William A. Johnson et al. · AIP conference proceedings · 1973 · 56 citations