Prospective randomised controlled trial comparing sub-threshold micropulse diode laser photocoagulation and conventional green laser for clinically significant diabetic macular oedema

João Figueira, Jaheed Khan, Sandrina Nunes, Sobha Sivaprasad, Andreia Rosa, Jose F. Abreu, José Cunha‐Vaz, Victor Chong

British Journal of Ophthalmology · 2008 · 192 citations · 15 references

Concepts

Abstract

AIM: The study was a prospective randomised controlled double-masked trial performed in two centres to compare sub-threshold micropulse diode laser photocoagulation (MPDL) with conventional green laser photocoagulation (CGL) in the treatment of clinically significant diabetic macular oedema (CSMO). METHODS: Fifty-three patients (84 eyes) with diabetic CSMO were randomly assigned to MPDL (n = 44) or CGL (n = 40) according to the modified Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. Treatments were performed after baseline and re-treatments were allowed at or after the 4 month visit if necessary. Parameters noted included the best corrected visual acuity (BCVA), colour fundus photographs, central retinal thickness using optical coherence tomography (OCT), vision contrast sensitivity with Pelli-Robson charts and presence of visible laser scars at baseline and at 4 and 12 months. The primary outcome was BCVA at 12 months. RESULTS: All patients completed 12 months of follow-up after treatment at baseline. There were no statistically significant differences in BCVA, contrast sensitivity and retinal thickness between the two laser modalities at 0, 4 and 12 months. We found that laser scarring was much more apparent with CGL than with the sub-threshold approach (MPDL). Laser scars were identified at the 12 month visits in 13.9% of the MPDL-treated eyes compared with 59.0% of the CGL-treated eyes (p<0.001). CONCLUSION: Sub-threshold micropulse diode laser photocoagulation is equally as effective as CGL treatment for CSMO. TRIAL REGISTRATION NUMBER: ISTRN 90646644.

References

15