Electroanalysis · 2004 · 52 citations · 25 references
Natural SciencesChemical EngineeringChemistryAnalytical ChemistryElectroanalytical MethodsElectrochemistryElectroanalytical ChemistryElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsElectrode MaterialsElectrode-electrolyte InterfacesAmperometric BiosensorsAmperometric DetectionAmperometric SensorsElectrochemical SensingElectrode StabilityGlassy Carbon ElectrodesPolymer ElectrodesVoltammetry
Abstract The polymer film of N,N ‐dimethylaniline (DMA) is deposited on the electrochemically pretreated glassy carbon (GC) electrode by continuous electrooxidation of the monomer. This poly N,N ‐dimethylaniline (PDMA) film‐coated electrode can be used as an amperometric sensor of ascorbic acid (AA). The polymer film (thickness ( ϕ ): 0.3±0.02 μm) having positive charge in its backbone attracts the anionic species AA. Thus, the anodic peak potential (350 mV vs. Ag|AgCl|NaCl (sat) ) for the oxidation of AA at the bare electrode is largely shifted to the negative value (150 mV) at this electrode. The PDMA film‐coated electrode is stable in acidic, alkaline and neutral media and can sense AA at different pH's. The diffusion coefficients of AA in solution ( D ) and in film ( D s ) were estimated by rotating disk electrode voltammetry: D =(5.5±0.1)×10 −6 cm 2 s −1 and D s =(6.3±0.2)×10 −8 , (6.0±0.2)×10 −8 and (4.7±0.2)×10 −8 cm 2 s −1 for 0.5, 1.5 and 3.0 mM AA, respectively. A permeability of AA through the PDMA film was found to decrease with increasing the concentration of AA in the solution. In the chronoamperometry, the current response for the oxidation of AA at different times elapsed after potential‐step application is linearly increased with the increase in AA concentration in a wide range of its concentration from 25 μM to 1.65 mM. In the hydrodynamic amperometry, a successive addition of 10 μM AA caused the successive increase in current response with equal amplitude and the sensitivity was calculated as 0.178 μA cm −2 μM −1 . So, the fouling of the electrode surface caused by the oxidized product of AA is markedly eliminated at this PDMA film‐coated electrode. A flow injection analysis based on the present electrode was performed to estimate the concentration of vitamin C in fruit juice.
25
Goodman and Gilman's The Pharmacological Basis of Therapeutics
Robert C. Hastings, Gillis W. Long · JAMA · 1991 · 1.1K citations
Harper's Review of Biochemistry
William N. Fishbein · Military Medicine · 1982 · 254 citations
Membrane-covered, rotated disk electrode
David Gough, John K. Leypoldt · Analytical Chemistry · 1979 · 230 citations
Oxidation of L-ascorbic acid on a gold electrode
M. Rueda, A. Aldaz, Francisco Sánchez-Burgos · Electrochimica Acta · 1978 · 154 citations