Applied Physics Letters · 2007 · 60 citations · 13 references
EngineeringElectrical EngineeringMaterials ScienceNanotechnologySemiconductor DevicesSemiconductor MaterialsHigh-frequency Semiconductor DevicesNanoelectronicsNanowiresQuantum DotsSemiconductor NanomaterialsSemiconductor PhysicsCurrent Measurement AccuracyElectronic TransportMeasurement AccuracyQuantum Dot DevicesQuantum Dot MaterialsSemiconductor Quantum Dots
Closely spaced local gate electrodes are used to electrically define a double quantum dot along an InAs nanowire crystal. By applying a periodic pulse sequence to two plunger gate electrodes controlling the double quantum dot charge configuration, the device is operated as a single electron pump. The authors find that within measurement accuracy, the pumping current equals one electron per cycle for frequencies up to 2MHz, demonstrating the suitability of nanowire based quantum dots for pumping applications.
13
Electron transport through double quantum dots
Wilfred G. van der Wiel, S. De Franceschi, J. M. Elzerman et al. · Reviews of Modern Physics · 2002 · 1.8K citations · Full text
Natural Sciences, Chemistry, Physics +16
Single-Electron Pump Based on Charging Effects
H. Pothier, P. Lafarge, C. Urbina et al. · Europhysics Letters (EPL) · 1992 · 504 citations
Accuracy of electron counting using a 7-junction electron pump
Mark W. Keller, John M. Martinis, Neil M. Zimmerman et al. · Applied Physics Letters · 1996 · 342 citations
Few-Electron Quantum Dots in Nanowires
Mikael Björk, Claes Thelander, Adam E. Hansen et al. · Nano Letters · 2004 · 287 citations