IEEE Journal of Quantum Electronics · 2013 · 59 citations · 39 references
Natural SciencesMaterials ScienceOptical MaterialsSpectroscopyWell TestingLaser SpectroscopyOptical Properties Of SolidsOptical SpectroscopyRaman SpectroscopyPump-probe SpectroscopyRaman AmplificationRaman ScatteringSteady-state GainStimulated Raman Scattering
The variation in the Raman gain coefficient in single-crystal diamond for pump wavelengths between 355 and 1450 nm is measured. Two techniques are used: a pump-probe approach giving an absolute measurement and a stimulated Raman oscillation threshold technique giving a relative measurement. Both approaches indicate that the Raman gain coefficient is a linear function of pump wavenumber. With the pump polarized along a <; 111 >; direction in the crystal, the Raman gain coefficient measured by the pump-probe technique is found to vary from 7.6 ± 0.8 for a pump wavelength of 1280 nm to 78 ± 8 cm/GW for a pump wavelength of 355 nm. With the established dependence of the Raman gain coefficient on the pump wavelength, the Raman gain coefficient can be estimated at any pump wavelength within the spectral range from 355 up to 1450 nm.
39
S. A. Solin, A. K. Ramdas · Physical review. B, Solid state · 1970 · 780 citations
The design and operation of solid-state Raman lasers
Helen M. Pask · Progress in Quantum Electronics · 2003 · 403 citations
Observation of stimulated Raman amplification in silicon waveguides
R. Claps, Dimitrios Dimitropoulos, Varun Raghunathan et al. · Optics Express · 2003 · 390 citations · Full text
High intensity Raman interactions
A. Laubereau, W. Kaiser · Progress in Quantum Electronics · 1979 · 303 citations