Applied Physics Letters · 2015 · 43 citations · 20 references
EngineeringBioengineeringPhysiologyBiosensorsPhysical ActivitySensorsBody CompositionElectrical CharacterizationSensor-based AnalysisWearable BiosensorsWearable Health TechnologiesChemical CharacteristicsConcentrationConductivitySweat BiomarkersSweat BiosensorsSweat PhysiologySweat Sample CollectionSweating Physiology
Dehydration is one of the most profound physiological challenges that significantly affects athletes and soldiers if not detected early. Recently, a few groups have focused on dehydration detection using sweat as the main biomarker. Although there are some proposed devices, the electrical and chemical characteristics of sweat have yet to be incorporated into the validations. In this work, we have developed a simple test setup to analyze artificial sweat that is comprised the main components of human sweat. We provide theoretical and experimental details on the electrical and chemical behavior of the artificial sweat for various concentration values within a temperature range of 5 °C to 50 °C. We have also developed an efficient sweat collecting and detection system based on 3D printing. Human studies were conducted and this particular protocol has shown that dehydration starts to take effect as early as 40 min into the physical activity if there is no fluid intake during the exercise. We believe that our device will lead to developing viable real-time sweat analysis systems.
20
Amay J. Bandodkar, Denise Molinnus, Omar Mirza et al. · Biosensors and Bioelectronics · 2013 · 485 citations · Full text
Recent developments in urea biosensors
Gunjan Dhawan, Gajjala Sumana, Bansi D. Malhotra · Biochemical Engineering Journal · 2008 · 204 citations