Optics Letters · 1994 · 27 citations · 16 references
Natural SciencesBiomedical EngineeringBiomedical ImagingDiagnostic ImagingSpectroscopyAbsorption SpectroscopyFlow MeasurementLaser SpectroscopyOptical SpectroscopyOptical TomographyAbsorption TomographyAccuracyFrequency ModulationOptical AbsorptionSensitivitySpatially Resolved AbsorptionTomographic ImagingTomographic Imaging Systems
Diode laser absorption measurements obtained with two-tone frequency-modulation spectroscopy (TTFMS) are combined with tomography to produce spatially resolved quantitative images of fluid flows. The high sensitivity, good accuracy, and high stability of TTFMS absorption measurements permit optical-absorption tomography to be performed with low noise on extremely weakly absorbing objects. The method is demonstrated on a small oxygen flow with a GaAlAs diode laser operating near 760 nm and with an absorption sensitivity of 1:10(6).
16
Optical tomography for flow field diagnostics
Robert J. Santoro, H.G. Semerjian, P. J. Emmerman et al. · International Journal of Heat and Mass Transfer · 1981 · 155 citations