Environmental RadiochemistryEnvironmental ChemistryAverage RadonEnvironmental MonitoringEngineeringRadiological SciencesMeasurementThoron Parallel MeasurementsOther Radon MeasurementsRadioanalytical ChemistryHungarian DetectorsRadio TelescopeNuclear MedicineRadiology
Hungarian detectors modified and developed at the National Institute of Radiological Sciences (NIRS), Japan were placed at different sites, including homes and underground workplaces in Hungary, in order to gain information on the average radon (222Rn) and thoron (220Rn) concentration levels. Measurements were carried out in dwellings in a village and a manganese mine in Hungary. The radon and thoron concentrations in the dwellings of the village in the summer period were found to be 154 (17-1083) and 98 (1-714) Bq m(-3), respectively. Considering the results of other radon measurements during the winter (814 Bq m(-3)) and summer (182 Bq m(-3)) periods, the thoron concentrations were also expected to be higher in winter. In the manganese mine, radon and thoron were measured at 20 points for 6 months, changing the detectors each month. The averages were 924 (308-1639) and 221 (61-510) Bq m(-3) for radon and thoron, respectively. These results showed significant variance with the date and place of the measurement.